$0.00
Tiger the leading VOC detector from ION Science boasts rapid, accurate detection of volatile organic compounds within the harshest of environments and a dynamic detection range. Tiger incorporates Ion Science patented PID sensor technology with ultimate resistance to humidity and contamination, proven to dramatically extend run time in the field. The Tiger is also available in the Ion Science Fire Investigation Kit for fire and arson analysis.
The Tiger handheld VOC detector is a handheld gas detection instrument for the rapid, accurate detection of volatile organic compounds (VOCs) within the harshest of environments.
Tiger's photoionisation detection (PID) sensor technology with humidity resistance and anti-contamination design dramatically extends run time in the field.
Dynamic detection range of 0 to 20,000 parts per million (ppm) with a minimum sensitivity of 0.001ppm (1 ppb),
Widest measurement range of any other VOC detector on the market.
Fastest response time on the market of just two seconds and is just as quick to clear down.
Connect directly to a PC via the USB for extremely fast data download capabilities.
Safe replacement of batteries in hazardous environments.
Long-life rechargeable Li-ion batteries give up to 24 hours of use.
Low-cost filters and lamps can be easily changed in seconds, minimising instrument downtime.
Inexpensive disposable parts mean the Tiger VOC detector has the lowest running costs on the market.
Tiger is a fully upgradeable VOC detector with multiple functions to choose from. A base unit can be upgraded with data logging, health and safety and ppb options, remotely, without needing to be returned to the factory.
Also available in the Fire Investigation Kit for fire and arson analysis. There are several good reasons to use a PID for arson investigation:
> PIDs are portable and battery powered making them ideal for field applications
> PIDs are a quick, simple to use and accurate method for the detection of accelerants at a fire scene
> PIDs are very sensitive to commonly found accelerants and will detect hundreds of gasses and vapours
> PIDs are non-destructive and will not affect the air sample which can be captured for further lab analysis
> PIDs reduce the quantity and cost of lab samples required to reach a conclusion as to the cause of the fire
Tiger offers simple, one-handed operation for easy VOC detection. Its rugged design and protective, removable rubber boot withstand the harshest environments.
No complex set up procedures via a PC to perform basic functions.
It's simple-to-use software features require minimal user training.
Ground-breaking PID ION Science technology is widely used and trusted by major gas detection manufacturers worldwide.
Contact Teltherm for guidance and selection advice in order to best serve your application.