Analytical Instrumentation

Analysers are a critical part of many process control and monitoring systems. Whether the reason is environmental compliance, product quality or safety, you rely on an analyser to tell you about the materials you use, produce or release. This page explains the main technologies used to analyse liquids, gases and solids, so you can see which suits your process. When you’re ready, our instrumentation specialists can help you choose the right analyser and keep it performing.

Browse Analytical Instruments


Liquid analysis


Liquid analysers measure the chemical and physical properties of water and process liquids. They’re used across water and wastewater treatment, food and beverage, dairy, chemical processing and environmental monitoring.

pH sensors

Suitable for: Liquids

pH sensors measure the hydrogen-ion activity of water-based solutions, showing how acidic or alkaline they are on a scale of 0 to 14. They’re widely used in water treatment, chemical, food and process applications, and pH can also be used to infer chemical concentration. A typical sensor pairs a glass measuring electrode with a reference electrode, and temperature compensation keeps readings accurate as process conditions change.

Conductivity analysers

Suitable for: Liquids

Conductivity analysers measure a liquid’s ability to carry an electrical current, reported as conductivity or resistivity. They suit both simple and complex processes, from high-purity water to acids and caustic cleaning solutions. Using a concentration curve or table, the analyser can calculate concentration from the known properties of the liquid.

Contacting sensors use electrodes immersed in the liquid. Where fouling or corrosion is a problem, toroidal (inductive) sensors measure without exposed electrodes, using two closely coupled coils immersed in the solution.

Ion-selective electrodes (ISE)

Suitable for: Liquids

Ion-selective electrodes measure the activity of one specific ion dissolved in a solution and convert it into an electrical potential. Based on the known properties of the liquid, this gives you the concentration of ions such as ammonium, nitrate, chloride, fluoride and sulfide, as well as some metals. ISEs are commonly used for nutrient monitoring in wastewater treatment and for environmental water quality.

Oxidation reduction potential (ORP)

Suitable for: Liquids

Oxidation reduction potential (ORP), also known as redox, measures a solution’s ability to oxidise or reduce another substance, expressed in millivolts. It’s a cost-effective way to monitor processes that contain oxidisers or reducers such as chlorine, ozone and bromine. ORP is often used to confirm disinfection performance in water treatment and to control chemical treatment of industrial wastewater. It shows how active the oxidiser or reducer is, rather than its exact concentration.

Dissolved oxygen (DO)

Suitable for: Liquids

Dissolved oxygen (DO) is the amount of oxygen dissolved in water, usually expressed in mg/L or percent saturation. It’s a key measurement in wastewater aeration, aquaculture and environmental water quality monitoring.

Two technologies are used: electrochemical (membrane) sensors and optical (luminescent) sensors. Optical sensors generally need less maintenance and don’t consume oxygen, while electrochemical sensors remain a proven, economical choice for many applications. In aeration control, accurate DO measurement can also help reduce blower energy use.

Turbidity and suspended solids

Suitable for: Liquids (including slurries)

Turbidity and suspended solids sensors use optical methods to measure the cloudiness of water caused by suspended particles. The sensor measures how light is scattered or absorbed and converts this into turbidity units, such as nephelometric turbidity units (NTU) or formazin nephelometric units (FNU), or into total suspended solids (TSS) in mg/L or ppm. These measurements are widely used in drinking water, wastewater, industrial and environmental applications.

Where solids content is very high or particle size varies widely, microwave or ultrasonic sensors can give a more reliable result than optical devices.

Gas analysis


Gas analysers measure the concentration of specific gases in combustion, emissions, process, biogas and gas purity applications, including oxygen, one of the most commonly measured gases of all. Alongside the general-purpose technologies below, zirconia and paramagnetic analysers are designed specifically for oxygen. The right technology depends on the target gas, its concentration range and the other gases in the sample.

Nondispersive infrared (NDIR) gas analysers

Suitable for: Gases

Nondispersive infrared (NDIR) analysers suit a wide range of gas measurements, including carbon dioxide, carbon monoxide and methane, each of which absorbs infrared light at known wavelengths. “Nondispersive” means the analyser doesn’t split the light into a spectrum with a prism or grating; instead, an optical filter passes only the wavelength of interest.

Sample gas flows through a measuring cell with an infrared source at one end and a detector at the other. The amount of light absorbed is proportional to the gas concentration and is converted into a measurement signal. A reference measurement, from a second cell filled with a non-absorbing gas or at a wavelength the gas doesn’t absorb, corrects for drift caused by temperature changes and component ageing.

Analysers with multiple filters or a rotating filter wheel can measure more than one gas at the same time. A related method, photoacoustic detection, measures the tiny pressure pulses produced as the gas absorbs infrared energy and warms, which are also proportional to concentration.

Ultraviolet (UV) gas analysers

Suitable for: Gases

Ultraviolet (UV) analysers work on a similar principle to NDIR analysers, but use ultraviolet light. They’re the better choice when the target gas doesn’t absorb enough infrared light, and they suit low concentrations and samples where water vapour would interfere with an infrared measurement. Typical measurements include sulfur dioxide, nitric oxide, nitrogen dioxide and hydrogen sulfide.

For some gases, a UV fluorescence method is used instead: the analyser measures the light the gas emits after absorbing UV energy.

Thermal conductivity (TC) analysers

Suitable for: Gases

Thermal conductivity (TC) analysers suit binary gas mixtures, where the target gas conducts heat noticeably differently from the background gas. The sample passes over a heated element, and the heat it carries away changes the element’s resistance, which is converted into a concentration reading. A second cell containing a fixed reference gas compensates for ambient changes, improving accuracy and reducing drift.

TC analysers are best suited to measuring hydrogen and helium at percentage levels, and can also measure gases such as argon and carbon dioxide, depending on the background gas. A common application is monitoring hydrogen purity in hydrogen-cooled generators.

Electrochemical gas analysers

Suitable for: Gases

Electrochemical analysers are a cost-effective and sometimes essential solution for gas concentrations from very low (ppm) to high percentage levels. A typical sensor has a gas-permeable membrane covering an electrolyte and several electrodes. As the target gas passes through the membrane, it reacts chemically and produces a small current that is proportional to its concentration.

Electrochemical sensors are consumable and are replaced periodically, much like a battery. Sensor life depends on sample flow, gas concentration, moisture and any background gases that could poison the sensor. With careful selection, sensors typically last from several months to several years.

Common applications include portable and fixed combustion analysis, area monitoring, process measurement and blanket gas analysis. For monitoring toxic and combustible gases to protect people, see our Gas Detection range.

Zirconia oxygen analysers

Suitable for: Gases

Zirconia oxygen sensors use a zirconium oxide (zirconia) ceramic cell with porous electrodes on each side. One side is exposed to reference air and the other to the process gas. Because the two sides have different oxygen levels, the cell produces a voltage (described by the Nernst equation) that is converted into an oxygen concentration.

Zirconia only conducts oxygen ions at high temperatures, so the cell is heated electrically or by the process itself, for example when installed directly in a flue or furnace. Zirconia sensors are rugged, respond quickly and measure from ppm to percentage levels, making them the standard choice for combustion control on boilers and furnaces. They aren’t suitable where the sample contains high levels of combustible gases, as these react on the hot cell and cause low readings.

Paramagnetic oxygen analysers

Suitable for: Gases

Paramagnetic analysers use a property that sets oxygen apart from most other gases: it is strongly attracted to a magnetic field. In the common dumbbell design, the sample passes through a strong magnetic field around a small glass dumbbell on a fine suspension. Oxygen in the sample pushes on the dumbbell with a force proportional to its concentration, and this is measured electronically.

Paramagnetic analysers are accurate across the full 0–100% range, respond quickly and have no consumable sensor. With a clean, dry sample and regular maintenance, they give long, reliable service in process, laboratory and gas purity applications.

Solids analysis


Solids analysers measure the moisture and other constituents, such as oil, fat and protein, of bulk and manufactured products. This once meant taking samples to a laboratory. Today’s analysers measure directly on the production line, giving you continuous data for process control, quality and compliance, even in harsh factory environments.

Near infrared (NIR) moisture and constituent analysers

Suitable for: Solids

Near infrared (NIR) analysers work on the same principle as many gas and liquid analysers: constituents absorb light at specific wavelengths. In the near infrared range, this gives high sensitivity to moisture, oil, fat, protein, resins and coatings.

The analyser directs light through a rotating wheel of narrow-band filters onto the product. Measurement filters target the constituent of interest, while reference filters compensate for changes in the product’s colour and texture. Light reflected from the product returns to a detector and is converted into a concentration reading.

Installation is non-contact: the analyser mounts above a conveyor or web, or views product in pipework or chutes through a window or sample port. Typical products include snack foods, minerals and wood chips. Because NIR light only penetrates the surface, it’s best suited to products where the surface is representative of the whole, such as powders, wood fibre and chips.

Radio frequency (RF) moisture analysers

Suitable for: Solids

Radio frequency (RF) moisture analysers use a dielectric measurement to determine the moisture content of a product. Because RF energy penetrates deep into the material, the reading reflects total moisture rather than just surface moisture, which matters when moisture isn’t evenly distributed. This makes RF analysers well suited to plasterboard, wood panels and food products such as wheat.

The sensor acts as an antenna and is available in configurations for high-temperature, solid, granular and viscous products, including bakery dough and honey.

Choosing the right analyser


There are many ways to make these measurements, so we focus on recommending reliable, technically advanced instruments that reduce complexity for your business. When recommending an analyser, we consider:

  • the properties of the liquid, gas or solid being measured
  • the process connection and mounting location
  • the pressure and temperature of the process and its surroundings
  • your preferred units of measurement and output signal
  • power, installation and maintenance requirements
  • hazardous area, compliance and certification requirements.

Which technology suits your measurement?

What you need to measure State Technology
Acidity or alkalinity Liquids pH sensors
Dissolved salts or chemical concentration Liquids Conductivity analysers
Specific ions, such as ammonium or nitrate Liquids Ion-selective electrodes
Disinfectant or oxidiser activity Liquids ORP
Oxygen dissolved in water Liquids Dissolved oxygen sensors
Cloudiness or suspended solids Liquids Turbidity and suspended solids sensors
Carbon dioxide, carbon monoxide or methane Gases NDIR analysers
Low levels of sulfur dioxide, nitrogen oxides or hydrogen sulfide Gases UV analysers
Hydrogen or helium in a binary mixture Gases Thermal conductivity analysers
Combustion gases with a portable analyser Gases Electrochemical analysers
Oxygen in a flue or furnace Gases Zirconia oxygen analysers
Oxygen purity from 0 to 100% Gases Paramagnetic oxygen analysers
Surface moisture, fat or protein on a conveyor Solids NIR analysers
Total moisture in board, grain or dough Solids RF moisture analysers

As well as supplying the right instrument, we can maintain and repair it for you. See our Calibration & Service page for more.

Frequently asked questions


Which analyser should I use to measure oxygen in a boiler flue?

A zirconia oxygen analyser is the usual choice. It can be installed directly in the flue, responds quickly and measures accurately at the high temperatures found in combustion processes.

What’s the difference between optical and electrochemical dissolved oxygen sensors?

Optical (luminescent) sensors generally need less maintenance and don’t consume oxygen during measurement. Electrochemical (membrane) sensors are a proven, economical option for many applications.

How often do electrochemical gas sensors need replacing?

It depends on the application. With careful selection, sensors typically last from several months to several years, depending on sample flow, gas concentration, moisture and background gases.

Can moisture be measured without touching the product?

Yes. Near infrared (NIR) analysers mount above a conveyor and measure moisture and other constituents without contact. Radio frequency (RF) analysers are used where total moisture, not just surface moisture, needs to be measured.

Explore our analytical instruments

Browse our range of liquid, gas and solids analysers, or talk to our team about your application.

View Analytical Instruments →
ISO 9001
Quality certified
IANZ accredited
Calibration support
Established expertise
Instrumentation specialists
NZ-based support
Technical product assistance


Need help choosing the right analyser?

Tell us what you need to measure, and our team will help you find the right solution.



    +64 9 633 0040